ONCOLOGY 2-WAY ADMINISTRATION LINE PVC DEHP-FREE WITH CHECK VALVE AND STOPPER

Reference : LA2VARPP

  • 2-way administration line with an air intake
  • Check valve and stopper
  • Yellow transparent tube with UV filter

Description

Administration line (2-way) for oncology treatments equipped with:

Perforator: Two-channel with grip wings
Air intake: Delivered closed - 1.2μ filter,

Check valve and stopper:
Safe use: administration of drugs; asepsis maintained by stopper,
Reliable and secure: Flow of the solution in the direction of the patient only, low opening pressure.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End fitting: for infusion spike (gravity or pump)

UV filter

Administration line for oncology treatments equipped with:

Perforator: Two-channel with grip wings
Air intake: Delivered closed - 1.2μ filter,

Check valve and stopper:
Safe use: administration of drugs; asepsis maintained by stopper,
Reliable and secure: Flow of the solution in the direction of the patient only, low opening pressure.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End fitting: for infusion spike (gravity or pump)

UV filter

Technical
information

Indications 
This product is designed to administer cytostatic drugs in a closed system. At the end of infusion, leave all bypasses connected and put them all into the circuit for eliminating contaminated devices in Oncology

Used materials 
PVC DINCH: Tubing - Acrylonitrile Butadiene Styrene: Perforator - Nylon: air intake - Acrylic: valve - Polyethylene: protective cap for perforator, end cap, stopper plug - Silicone: valve - POM: clamp - PVC: 3-way connector

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

economic operator 

  • MANUFACTURER : DIDACTIC / 216 Rue Roland Moreno - 76210 Saint-Jean-de-

Logistics
information

Transport conditions 

Protected from light, humidity and heat

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 3661809018565
BOX 50 29 x 39 x 20 1.098 3661809118562
CASE 200 41 x 61 x 43 5.098 3661809218569

Administration line (2-way) for oncology treatments equipped with:

Perforator: Two-channel with grip wings
Air intake: Delivered closed - 1.2μ filter,

Check valve and stopper:
Safe use: administration of drugs; asepsis maintained by stopper,
Reliable and secure: Flow of the solution in the direction of the patient only, low opening pressure.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End fitting: for infusion spike (gravity or pump)

UV filter

Administration line for oncology treatments equipped with:

Perforator: Two-channel with grip wings
Air intake: Delivered closed - 1.2μ filter,

Check valve and stopper:
Safe use: administration of drugs; asepsis maintained by stopper,
Reliable and secure: Flow of the solution in the direction of the patient only, low opening pressure.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End fitting: for infusion spike (gravity or pump)

UV filter

Indications 
This product is designed to administer cytostatic drugs in a closed system. At the end of infusion, leave all bypasses connected and put them all into the circuit for eliminating contaminated devices in Oncology

Used materials 
PVC DINCH: Tubing - Acrylonitrile Butadiene Styrene: Perforator - Nylon: air intake - Acrylic: valve - Polyethylene: protective cap for perforator, end cap, stopper plug - Silicone: valve - POM: clamp - PVC: 3-way connector

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

economic operator 

  • MANUFACTURER : DIDACTIC / 216 Rue Roland Moreno - 76210 Saint-Jean-de-

Transport conditions 

Protected from light, humidity and heat

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 3661809018565
BOX 50 29 x 39 x 20 1.098 3661809118562
CASE 200 41 x 61 x 43 5.098 3661809218569

Video(s)

Associated products

ONCOLOGY 4-WAY ADMINISTRATION LINE PVC DEHP-FREE WITH CHECK VALVE AND STOPPER
ONCOLOGY 1-WAY ADMINISTRATION LINE PVC DEHP-FREE PHOTOPROTECTION WITH CHECK VALVE AND STOPPER
ONCOLOGY 1-WAY ADMINISTRATION LINE PVC DEHP-FREE PHOTOPROTECTION BI-DIRECTIONAL VALVE

Associated products

ONCOLOGY 4-WAY ADMINISTRATION LINE PVC DEHP-FREE WITH CHECK VALVE AND STOPPER
ONCOLOGY 1-WAY ADMINISTRATION LINE PVC DEHP-FREE PHOTOPROTECTION WITH CHECK VALVE AND STOPPER
ONCOLOGY 1-WAY ADMINISTRATION LINE PVC DEHP-FREE PHOTOPROTECTION BI-DIRECTIONAL VALVE

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.